compact medium power amplifier for emi/emc test and measurement applications 45 river drive georgetown, ontario, canada l7g 2j4 tel: +1 (905) 877-0161 fax: +1 (905) 877-5327 e-mail: marketing@satcom.cpii.com www.cpii.com/satcom compact five rack units tall (8.75 in, 222 mm) versatile ultra-wideband, automatic fault recycle, user- friendly microprocessor-controlled logic with integrated computer interface, digital metering, electronic variable attenuation, soft-fail when subjected to extreme load swr conditions, quiet operation for laboratory environment. an integral solid state pre-ampli? er and ieee interface are included as standard features. the vzs/c-6963j2 series compact hpa, with 250w or 340w traveling wave tube global applications 230 vac operation. meets international safety standard en61010 and electromagnetic compatibility 89/336/eec. worldwide support modular design and built-in fault diagnostic capability, backed by cpis worldwide 24-hour customer support network that includes ? fteen regional factory service centers. compact medium power amplifier 2.0 - 8.0 ghz 2.0 - 8.0 ghz
2.0 - 8.0 ghz for more detailed information, please refer to the corresponding cpi technical description. note: speci cations may change without notice as a result of additional data or product re nement. please contact cpi before using this information for system design. mkt 224, issue 1 09/07 pdf options: ? input isolator (-1 db gain) ? remote control panel ? 115 vac external step-up transformer certificate number: 30515 specifications, vzs/c-6963j2 electrical frequency 2.0 to 8.0 ghz output power twt 250 w or 340 w min. flange 225 w or 300 w min. bandwidth 6.0 ghz gain 54 db min. at rated power output; 56 db typ. at small signal rf level adjust 0 to 20 db continuous gain stability 0.25 db/24 hr max. (at constant drive and temp.) gain variation 12.0 db pk-pk max. over the 6.0 ghz bandwidth, typ. input vswr 2.5:1 typ. 1.7:1 max. (with optional input isolator) output vswr 2.5:1 typ. load vswr 1.5:1 max. for full spec compliance; 2.0:1 max. continuous operation; any value without damage residual am -50 dbc below 10 khz; -20 [1.3 + log f (khz)] dbc, 10 khz to 500 khz; -85 dbc above 500 khz phase noise meets iess-308/309 with 3 db margin noise and spurious -50 dbc typ. excluding harmonics harmonic content -3 dbc typical at lower band edge primary power 220-240 vac 10%, single phase, 47-63 hz power consumption 2.6 kva typ. 3.0 kva max. inrush current 200% max. environmental (operating) ambient temperature -10 to +40c operating relative humidity 95% non-condensing altitude up to 10,000 ft (3000 m) with standard adiabatic derating of 2/1000 ft. shock and vibration designed to meet conditions normally encountered in the laboratory acoustic noise 65 dba @ 3 ft. from ampli? er mechanical cooling (twt) forced air with integral blower. rear air intake and exhaust. rf input connection type n female rf output connection type n female rf power monitors type-n female, -50 db nominal dimensions (w x h x d) 19 x 8.75 x 26 in. (483 x 222 x 661 mm) weight 110 lbs (50 kg) safety en61010
|